Using the OP, select the vertical softkey Delete password. Using the OP, select the vertical softkey Password …ġ1. Using the OP, select the horizontal softkey Start-up.ġ0.

Using OP, (Operator Panel) select hardkey Machine then Menu selectĩ. SINUMERIK 840D/810D Deactivating Password Access RightsĨ. See procedure Deactivating Password Access Rights. When finished creating or reading in Series Start-up the password access rights should be deactivated. Using the OP, select the Menu select twice to return to the previous operating area I.e. Observe: Message “Current access level: Manufact. Note: On some panels you may need to hold the hardkey (Shift) to type characters Using the OP, type in SUNRISE (in upper case). Observe: Define password window appears with text “Please enter password:”ĥ. Using the OP, select the vertical softkey Set password. Using the OP, select the vertical softkey Password …Ĥ. Observe: Message: Area Start-up being loaded! Please wait …ģ. Using the OP, select the horizontal softkey Start-up. SINUMERIK 840D/810D Setting Password Access RightsĢ. If necessary, repeat steps 6 and 7, selecting the appropriate archive file, to load both the NC and the PLC. The control will shift back to the Read Series Start-up Archive display.Ĩ. The message ‘NC Reset – Please wait’ will now appear as many as 6 times. A series of prompts will appear, telling you the status of the upload of the various series start-up files from the NC archive. Answer the query ‘Do you wish to perform a series start-up?’ By pressing the vertical softkey Yes. Observe: The window will shift to the Job Log display. Using OP, press the vertical softkey Start. Suggestion: Select a file which refers to the NC or PLC and has the most recent dateħ. Note: The backup files are created by the builder and / or end user and the specific name may vary. Using OP cursor keys highlight the appropriate NC or PLC archive file. Observe: A new window will appear, labeled Read Series Start-up Archive.Ħ. Using OP, select vertical softkey Read start-up archive NOTE: If Display shows Read startup archive window, skip step 5ĥ. Observe: Display shows ‘Create series startup archive’ window. Using OP, select horizontal softkey Series start-up. See the procedure Setting Password Access rights. NOTE: If softkey Series start-up does not appear then the password access rights need to be set. Observe: Horizontal softkey menu contains a key labeled Series start-up Using OP, select the hardkey (etc…/extension of the softkey menu key). Observe: Current operating area is displayed at top left of display.ģ. Machine, Parameter, Program, Services, Diagnosis and Start-up. Observe: The main operating areas horizontal softkey menu appears.

Using OP, (Operator Panel) select hardkey Machine then Menu select Reloading Siemens Sinumerik Start-up Archive Files for the NC and PLCġ.